1006 DC Millivolt Source

Product By Flir Logo
  • The 1006 is an accurate handheld millivolt source suitable for voltage injection applications. Three output ranges are provided to give adjustable output values from 1 µV to 1 V with a basic 0.02 ?curacy. For signal injection, the operator needs to switch on, check the battery condition, select the range, and set the required voltage using the thumbwheel switches. The 1006 uses a precision reference diode and low temperature coefficient resistors to give a highly stable output.

    Power is provided by 6 AA batteries. Battery life is several months, depending on usage. The battery condition is monitored by an indicator mounted on the top of the unit. The 1006 has up to 20 mA drive current and is short circuit and overload protected. An off/normal/reverse output polarity switch is provided.

    Safety Terminals
    Fitted as standard and fully compatible with 4 mm shrouded plugs, as well as standard plugs, bare wires, and spade terminals.

    Added Protection
    The 1006 comes fitted with an ergonomic rubber cover providing increased protection and durability. It has a textured grip for comfortable handling and openings at the top and bottom to allow access to the battery meter and a position to place labels if required. It is easy to remove if the user prefers a stand-alone unit or to house the 1006 in the 9027 carry case.

    Applications
    As an accurate millivolt source, the 1006 can be used for many applications including thermocouple simulation (using appropriate lookup table), chart recorder calibration, A/D converter and DMM calibration, and as a stable voltage for backing off DC offsets.

    The 1006 is an easy to use calibration instrument designed for accuracy and reliability. As part of the Time Electronics portable test equipment range it is ideal for use in the lab or field. 

Output

0 to 999.9mV in 3 ranges:
1 V range: 0 to 999.9 mV in 0.1 mV steps.
100 mV range: 0 to 99.99 mV in 10 ?V steps.
10 mV range: 0 to 9.999 mV in 1 ?V steps.

Accuracy

± (0.02 % of setting + 0.02 % of range + 1 ?V).

Output Resistance

Less than 0.2 ? on 1 V and 100 mV ranges. 1 ? on 10 mV range.

Maximum Output Current

1 V and 100 mV ranges: 20 mA. 10 mV range: Up to short circuit value although it should be noted that loads of less than 1 k? will give greater than 0.1 % error.

Output Voltage Stability

Less than 60 ppm/°C.  Less than 100 ppm per 3 months (non-cumulative).

Output Polarity

Positive or negative switch selected.  A centre ‘off’ position is also provided.

Output Noise Level

Less than 30 ppm of full scale

Reference Source

Precision zener diode, selected for stability and low temperature coefficient.

Maximum Overload

The instrument can withstand continuous short circuit on the output for all ranges.

Power Supply

6-AA size (51 x 14 mm) batteries. A battery condition display indicates when the batteries should be changed.
An alternative power source is 6 NiMH cells of the same dimensions. These can be recharged via a socket on the top of the unit. The 6 rechargeable batteries and mains recharger are available as an optional extra.


Operating Temperature

–10 °C to 60 °C

Dimensions

H 200 x W 75 x D 110 mm (H 215 x W 100 x D 120 mm including protective boot)

Weight

0.75 kg (1.1 kg including protective boot)

Supplied With

Protective cover (fitted), 6 x AA batteries (installed), and user manual

Optional Extras

Carry case, rechargeable battery pack (240 V or 110 V mains), traceable and accredited calibration certificates

Country of OriginUK